HIGH PERFORMANCE LIQUID CHROMATOGRAPHY FILETYPE PDF

HPLC is a form of liquid chromatography used to separate compounds that are dissolved in solution. HPLC instruments consist of a reservoir of mobile phase. The differences between High Performance Liquid Chromatography and Gas The components of the high performance liquid chromatograph (HPLC). High-performance liquid chromatography (HPLC) is a type of liquid chromatography used to separate and quantify com- pounds that have been dissolved in.

Author: Babei Aradal
Country: Zimbabwe
Language: English (Spanish)
Genre: Technology
Published (Last): 14 January 2009
Pages: 59
PDF File Size: 17.76 Mb
ePub File Size: 9.52 Mb
ISBN: 219-8-64686-298-5
Downloads: 32614
Price: Free* [*Free Regsitration Required]
Uploader: Tubei

The components of a basic high-performance liquid chromatography [HPLC] system are shown in the simple diagram in Figure E. A reservoir holds the solvent [called the mobile phase, because it moves].

A high-pressure performnace [solvent delivery system or solvent manager] is used to generate and meter a specified flow rate of mobile phase, typically milliliters per minute.

An injector [sample manager or autosampler] is able to introduce [inject] the sample into the continuously flowing mobile phase liqiid that carries the sample into the HPLC column. The column contains the chromatographic packing material needed perormance effect the separation. This packing material is called the stationary phase because it is held in place by the column hardware. A detector is needed to see the separated compound bands as they elute from the HPLC column [most compounds have no color, so we cannot see them with our eyes].

The mobile phase exits the detector chromatgoraphy can be sent to waste, or collected, as desired. When the mobile phase contains a separated compound band, HPLC provides the ability chromtaography collect this fraction of the eluate containing that purified compound for further study. Note that high-pressure tubing and fittings are used to interconnect the pump, injector, column, and detector components to form the conduit for the mobile phase, sample, and separated compound bands.

The detector is wired to the computer data station, the HPLC system component that records the electrical signal needed to generate the chromatogram on its display and to identify and quantitate the tiletype of the sample constituents see Figure F. Since sample compound characteristics can be very different, several types of detectors have been developed. For example, if a compound can absorb ultraviolet light, a UV-absorbance detector is used.

If the compound fluoresces, a fluorescence detector is used. If the compound does not have either of these characteristics, chromatograpyy more universal type of detector is used, such as an evaporative-light-scattering detector [ELSD].

The most powerful approach is the use multiple detectors in series. This provides, from a single injection, more comprehensive information about an analyte.

High-performance liquid chromatography

HPLC Operation A simple way to understand how we achieve the separation of the compounds contained in a sample is to view the diagram in Figure G. Mobile phase enters the column from the left, passes through the particle bed, and exits at the right. Flow direction is represented by green arrows. First, consider the top image; it represents the column at time zero [the moment of injection], when the sample enters the column and begins to form a band. The sample shown here, a mixture of yellow, red, and blue dyes, appears at the inlet of the column as a single black band.

  DIGIDESIGN VENUE SC48 MANUAL PDF

After a few minutes [lower image], during which mobile phase flows continuously and steadily past the packing material particles, we can see that the individual dyes have moved in separate bands at different speeds. This is because there is a competition between the mobile phase and the stationary phase for attracting each of the dyes or analytes. Notice that the yellow dye band moves the fastest and is about to exit the column.

The yellow dye likes [is attracted to] the mobile phase more than the other dyes. Therefore, it moves at a faster speed, closer to that of the mobile phase. The blue dye band likes the packing material more than the mobile phase. Its stronger attraction to the particles causes it to move significantly slower.

In other words, it is the most retained compound in this sample mixture. The red dye band has an intermediate attraction for the mobile phase and therefore moves at an intermediate speed through the column. Since each dye band moves at different speed, we are able to separate it chromatographically. What Is a Detector? As the separated dye bands leave the column, they pass immediately into the detector.

The detector contains a flow cell that sees [detects] each separated compound band against a background of mobile phase [see Figure H]. A choice is made among many different types of detectors, depending upon the characteristics and concentrations of the compounds that need to be separated and analyzed, as discussed earlier.

High performance liquid chromatography (HPLC) | HiQ

What Is a Chromatovraphy A chromatogram is a representation of the separation that has chemically [chromatographically] occurred in the HPLC system. A series performancf peaks rising from a baseline is drawn on a time axis. Each peak represents the detector response for a different compound. The chromatogram is plotted by the computer data station [see Figure H].

In Figure H, the yellow band has completely passed through the detector flow cell; the electrical signal generated has been sent to the computer data station. The resulting chromatogram has begun to appear on screen. Note that the chromatogram begins when the sample was first injected and starts as a straight line set near the bottom of the screen.

This is called the baseline; it represents pure mobile phase passing through the flow cell over eprformance. As the yellow analyte band passes through the flow cell, a stronger signal is sent to the computer.

The line curves, first upward, and then downward, in proportion to the concentration of the yellow dye in the sample band. This creates a peak in the chromatogram. After the yellow band passes completely out of the detector cell, the signal level returns to the baseline; the flow cell now has, once again, only pure mobile phase in it.

Since the yellow band moves fastest, eluting first from the column, it is the first peak drawn. A little while later, the red band reaches the flow cell. The signal rises up from the baseline as the red filrtype first enters the cell, and the peak representing the red band begins to be drawn.

  LEIDRAAD CARDIOLOGIE PDF

In this fieltype, the red band has not fully passed through the flow cell.

How Does High Performance Liquid Chromatography Work?

The diagram shows what the red band and red peak would look like if we stopped the process at this moment. Since most of the red band has passed through the cell, most of the peak has been drawn, as shown by the solid line. If we could restart, the red band would completely pass through the flow cell and the red peak would be completed [dotted line].

The blue band, the most strongly retained, travels at the slowest rate and elutes after the red band. The dotted line shows you how the completed chromatogram would appear if we had let the run continue to its conclusion. It is interesting to note that the width of the blue peak will be the broadest because the width of the blue analyte band, while narrowest on the column, becomes the widest as it elutes from the column.

This is because it moves more slowly through the chromatographic packing material bed and requires more time [and mobile phase volume] to be eluted completely. Since mobile phase is continuously flowing at a fixed rate, this means that the blue band widens and is more dilute. Since the detector responds in proportion to the concentration of the band, the blue peak is lower in height, but larger in width. Why treat them the same?

On-Demand Webinar Available Now! Lessons from Newborn Screening MS Imaging for Biomedical Research Understand molecular visualization and spatial distribution of compounds. Increase detection selectivity and confidence using mass detection. Innovation through collaboration at our Experience Design Center.

Ask the Column Coach: Download or order your copy today. Behind liqkid Science Talking with analytical scientists who are trying to solve today’s toughest problems.

We ask, “how’d you do it? Material Safety Data Perforrmance. Empower tip-of-the-week blog and newsletter. Technique Reversed-Phase Liquid Chromat Supercritical CO2 Based Techn Run your small scale chiral purification and analysis in a single, easy-to-use platform.

Download the application note. Can’t find a course? View the complete course list. View US Courses Schedule. Meet the Experts Webinar Series. Beginners Guide to Preparative LC.

Practical Approaches to Peptide Isolation. Search Waters KnowledgeBase – find answers to your troubleshooting questions. Blogging About What’s Possible Read and follow the Waters blog for insights on how to use preformance and how customers use — our technologies, including Empower